HPS-TCP120
Product introduction
– High repeat accuracy & reliability
– Repeat accuracy: up to 0.005mm
– Detection range: 120mm
– Simultaneous calibration and precise positioning of X, Y, Z axes
– No post – installation calibration needed
– Compact integrated design
– Single – interface for all signal comms, easy wiring & installation
– Automatic background light compensation, strong – light resistant
– Ultra – short response time
– Switch detection freq.: 2.5kHz
– IP67 industrial – grade protection
Power Supply Voltage | DC+12~+30V | Current Consumption | Max. 30 mA*1 |
Output | 2x PNP-NO/2x NPN-NO | Output Status Display | Yellow Led |
Operating Temperature | -20~+75℃ | Laser Type | 650nm |
Laser Class | Class II | Switching Frequency | Max. 2500Hz |
Resolvable Object Diameter | 0.2mm | Repeatability | <0.005mm |
Shell Material | Aluminum, black anode oxidized surface | Interface | M7 aviation plug |
Size | 170(L)x170(W)x15mm(H), excluding the interface | Cable | M7 straight connector, φ4.6mm, 4 - pin |
Cable Length | 10m |